Had a break in - and discovered a flaw in Ring design

That's just completely wrong. From the Honeywell manual for a Vista 20p (most other real alarms support similar zone types)

Type 04 Interior Follower

  • Assign to a zone covering an area such as a foyer, lobby, or hallway through which one must pass upon entry (to and from the keypad).
  • Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit zone is faulted first. Otherwise this zone type gives an instant alarm.

Type 10 Interior w/Delay

  • Provides entry delay (using the programmed entry time), if tripped when the panel is armed in the Away mode.
  • Entry Delay 1 begins whenever sensors in this zone are violated, regardless of whether or not an entry/exit delay zone was tripped first.